It is mainly used to manufacture outer covering cladding layer of copper-clad aluminium conductor. As the inner conductor core wire of RF cable, it transfers signal
Mark | GB | JIS | ASTM | ||||||||||
TU0、TU1、TU2、T2 | C1020、C1100 | C10200、C10300、C10910、C11000 | |||||||||||
Executive standard | GB/T2059、JISH3100、ASTMB152 | ||||||||||||
Main application | It is mainly used to manufacture outer covering cladding layer of copper-clad aluminium conductor. As the inner conductor core wire of RF cable, it transfers signal | ||||||||||||
Thickness range (mm) |
| 0.2-0.35 | 0.35-0.5 | ||||||||||
tolerance | ±0.005 | ±0.008 | |||||||||||
Width range (mm) |
| Determined by the demand | |||||||||||
tolerance | ±0.1 | ||||||||||||
Strength of extense (MPa) | ≥230 | ||||||||||||
Ductility (%) | ≥30 | ||||||||||||
Vickers hardness(HV) | 50-65 | ||||||||||||
Electric conductivity (%IACS) | ≥99 |